Viessmann FA: Fan Does Not Stop

What the Viessmann FA fault means, what causes it, and why it's a job for a licensed BC gas technician — not a DIY reset.

Severity

Moderate — book a service visit

Combustion-fan fault

Gas safety first

This fault involves gas, combustion or venting. If you smell gas (rotten-egg odour), hear hissing, or feel unwell, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Do not flip switches or relight anything. For all other cases, switch the boiler off and call a licensed gas technician.

What the Viessmann FA fault means

The fan continued to run when it should have stopped, indicating a fan or control fault.

On Viessmann Vitodens 100-W, 200-W and 222-F series, FA is a combustion-fan fault. It is a protective response — the boiler is telling you something needs attention, and the safe, lasting fix is a proper diagnosis rather than repeated resets.

Symptoms you may notice

  • No heat or hot water
  • Boiler will not begin its ignition sequence
  • Unusual fan noise or no fan sound at all

Common causes of Viessmann FA

Fan feedback fault
Wiring issue
Control-board output fault

Why this is not a DIY fix

The combustion fan controls the air–gas ratio. A fan or fan-speed-feedback fault means the boiler cannot prove safe airflow, so it (correctly) refuses to fire. Replacing and re-commissioning the fan involves combustion verification — licensed gas work.

In British Columbia, gas work must be performed by a TSBC-licensed gas fitter. GasBoilers.ca — a CanroHeat division — sends Red Seal–certified, gas-licensed technicians who diagnose the true cause, repair it correctly, and verify safe operation before they leave.

How our technicians diagnose & repair it

  1. 1Test fan power, speed feedback (Hall sensor) and wiring
  2. 2Inspect the fan and venturi for debris, dust or seized bearings
  3. 3Check the control board fan-drive output
  4. 4Replace the fan if needed and re-run combustion analysis

Viessmann FA — FAQ

What does the Viessmann FA fault mean?

The fan continued to run when it should have stopped, indicating a fan or control fault. On Viessmann Vitodens 100-W, 200-W and 222-F series, this is categorised as a combustion-fan fault.

What causes Viessmann FA?

The most common causes are: Fan feedback fault; Wiring issue; Control-board output fault. A licensed technician confirms which one applies before any part is replaced.

Can I fix Viessmann FA myself?

No. The combustion fan controls the air–gas ratio. A fan or fan-speed-feedback fault means the boiler cannot prove safe airflow, so it (correctly) refuses to fire. Replacing and re-commissioning the fan involves combustion verification — licensed gas work. Repeatedly resetting the boiler without fixing the root cause can be unsafe and can cause further damage. Call GasBoilers.ca at 604-359-1081 for a licensed diagnosis.

Is the Viessmann FA fault dangerous?

It can be. This fault involves combustion, gas or venting. If you ever smell gas, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Otherwise, switch the boiler off and book a licensed technician.

How much does it cost to fix Viessmann FA in Greater Vancouver?

Cost depends on the root cause and any parts needed. We start with a flat-rate diagnostic, then quote the repair before any work begins — no surprises. Call 604-359-1081 for current pricing and same-day availability.

Viessmann showing FA? We'll fix it right.

Licensed, Red Seal–certified gas technicians across Greater Vancouver. Upfront pricing, same-day service available.

Call NowFree Quote
After-Hours Emergency604-359-1081