Viessmann F31: Temperature Sensor Open Circuit

What the Viessmann F31 error code means, what causes it, and why it's a job for a licensed BC gas technician — not a DIY reset.

Severity

Moderate — book a service visit

Temperature-sensor fault

What the Viessmann F31 error code means

A temperature sensor is reading an open circuit (disconnected or failed).

On Viessmann Vitodens 100-W, 200-W and 222-F series, F31 is a temperature-sensor fault. It is a protective response — the boiler is telling you something needs attention, and the safe, lasting fix is a proper diagnosis rather than repeated resets.

Symptoms you may notice

  • Erratic heating or hot-water temperature
  • Boiler locks out or refuses to fire
  • Wrong temperature shown on the display

Common causes of Viessmann F31

Failed sensor
Broken wire
Loose connector

Why this is not a DIY fix

A faulty NTC/thermistor reading (open, shorted or out-of-range) can mask a real overheating or circulation problem. A technician verifies whether the sensor itself has failed or whether it is correctly reporting a deeper fault before any part is replaced.

In British Columbia, gas work must be performed by a TSBC-licensed gas fitter. GasBoilers.ca — a CanroHeat division — sends Red Seal–certified, gas-licensed technicians who diagnose the true cause, repair it correctly, and verify safe operation before they leave.

How our technicians diagnose & repair it

  1. 1Measure sensor resistance against the manufacturer temperature curve
  2. 2Inspect wiring, connectors and sensor mounting/contact
  3. 3Confirm actual water temperature with calibrated instruments
  4. 4Replace the sensor and verify correct readings across the range

Viessmann F31 — FAQ

What does the Viessmann F31 error code mean?

A temperature sensor is reading an open circuit (disconnected or failed). On Viessmann Vitodens 100-W, 200-W and 222-F series, this is categorised as a temperature-sensor fault.

What causes Viessmann F31?

The most common causes are: Failed sensor; Broken wire; Loose connector. A licensed technician confirms which one applies before any part is replaced.

Can I fix Viessmann F31 myself?

No. A faulty NTC/thermistor reading (open, shorted or out-of-range) can mask a real overheating or circulation problem. A technician verifies whether the sensor itself has failed or whether it is correctly reporting a deeper fault before any part is replaced. Repeatedly resetting the boiler without fixing the root cause can be unsafe and can cause further damage. Call GasBoilers.ca at 604-359-1081 for a licensed diagnosis.

Is the Viessmann F31 error code dangerous?

This is a protective fault — the boiler has shut down a function to protect itself. It is best diagnosed promptly by a licensed technician so the underlying cause does not lead to a more expensive failure.

How much does it cost to fix Viessmann F31 in Greater Vancouver?

Cost depends on the root cause and any parts needed. We start with a flat-rate diagnostic, then quote the repair before any work begins — no surprises. Call 604-359-1081 for current pricing and same-day availability.