Noritz 72: Flame-Sensing Fault

What the Noritz 72 error code means, what causes it, and why it's a job for a licensed BC gas technician — not a DIY reset.

Severity

Moderate — book a service visit

Flame failure

Gas safety first

This fault involves gas, combustion or venting. If you smell gas (rotten-egg odour), hear hissing, or feel unwell, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Do not flip switches or relight anything. For all other cases, switch the boiler off and call a licensed gas technician.

What the Noritz 72 error code means

The flame-sensing circuit reported an abnormal reading.

On Noritz NCC combi and condensing series, 72 is a flame failure. It is a protective response — the boiler is telling you something needs attention, and the safe, lasting fix is a proper diagnosis rather than repeated resets.

Symptoms you may notice

  • Boiler fires briefly then shuts down
  • Intermittent heat or hot water
  • Short-cycling with lockouts

Common causes of Noritz 72

Dirty/failed flame rod
Wiring/grounding fault
Board fault

Why this is not a DIY fix

Loss-of-flame and false-flame faults point to the flame-rectification circuit, a dirty flame sensor, a failing gas valve, or unstable combustion. Confirming the cause needs live flame-current (microamp) readings and combustion analysis — instrumented gas work reserved for licensed technicians.

In British Columbia, gas work must be performed by a TSBC-licensed gas fitter. GasBoilers.ca — a CanroHeat division — sends Red Seal–certified, gas-licensed technicians who diagnose the true cause, repair it correctly, and verify safe operation before they leave.

How our technicians diagnose & repair it

  1. 1Measure flame-rectification current (microamps) during firing
  2. 2Clean or replace the flame-sensing electrode and check its ground path
  3. 3Inspect the burner and heat exchanger for sooting or fouling
  4. 4Verify gas pressure and re-run combustion analysis

Noritz 72 — FAQ

What does the Noritz 72 error code mean?

The flame-sensing circuit reported an abnormal reading. On Noritz NCC combi and condensing series, this is categorised as a flame failure.

What causes Noritz 72?

The most common causes are: Dirty/failed flame rod; Wiring/grounding fault; Board fault. A licensed technician confirms which one applies before any part is replaced.

Can I fix Noritz 72 myself?

No. Loss-of-flame and false-flame faults point to the flame-rectification circuit, a dirty flame sensor, a failing gas valve, or unstable combustion. Confirming the cause needs live flame-current (microamp) readings and combustion analysis — instrumented gas work reserved for licensed technicians. Repeatedly resetting the boiler without fixing the root cause can be unsafe and can cause further damage. Call GasBoilers.ca at 604-359-1081 for a licensed diagnosis.

Is the Noritz 72 error code dangerous?

It can be. This fault involves combustion, gas or venting. If you ever smell gas, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Otherwise, switch the boiler off and book a licensed technician.

How much does it cost to fix Noritz 72 in Greater Vancouver?

Cost depends on the root cause and any parts needed. We start with a flat-rate diagnostic, then quote the repair before any work begins — no surprises. Call 604-359-1081 for current pricing and same-day availability.

Noritz showing 72? We'll fix it right.

Licensed, Red Seal–certified gas technicians across Greater Vancouver. Upfront pricing, same-day service available.

Call NowFree Quote
After-Hours Emergency604-359-1081