Lochinvar Flame Loss: Flame Loss / Flame Circuit Fault

What the Lochinvar Flame Loss fault means, what causes it, and why it's a job for a licensed BC gas technician — not a DIY reset.

Severity

High — needs prompt professional attention

Flame failure

Gas safety first

This fault involves gas, combustion or venting. If you smell gas (rotten-egg odour), hear hissing, or feel unwell, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Do not flip switches or relight anything. For all other cases, switch the boiler off and call a licensed gas technician.

What the Lochinvar Flame Loss fault means

Flame was lost during operation, or the flame-sensing circuit reported a fault.

On Lochinvar Knight, WHN and SMART System series, Flame Loss is a flame failure. It is a protective response — the boiler is telling you something needs attention, and the safe, lasting fix is a proper diagnosis rather than repeated resets.

Symptoms you may notice

  • Boiler fires briefly then shuts down
  • Intermittent heat or hot water
  • Short-cycling with lockouts

Common causes of Lochinvar Flame Loss

Dirty flame rod
Unstable gas pressure
Wiring/grounding
Combustion fault

Why this is not a DIY fix

Loss-of-flame and false-flame faults point to the flame-rectification circuit, a dirty flame sensor, a failing gas valve, or unstable combustion. Confirming the cause needs live flame-current (microamp) readings and combustion analysis — instrumented gas work reserved for licensed technicians.

In British Columbia, gas work must be performed by a TSBC-licensed gas fitter. GasBoilers.ca — a CanroHeat division — sends Red Seal–certified, gas-licensed technicians who diagnose the true cause, repair it correctly, and verify safe operation before they leave.

How our technicians diagnose & repair it

  1. 1Measure flame-rectification current (microamps) during firing
  2. 2Clean or replace the flame-sensing electrode and check its ground path
  3. 3Inspect the burner and heat exchanger for sooting or fouling
  4. 4Verify gas pressure and re-run combustion analysis

Lochinvar Flame Loss — FAQ

What does the Lochinvar Flame Loss fault mean?

Flame was lost during operation, or the flame-sensing circuit reported a fault. On Lochinvar Knight, WHN and SMART System series, this is categorised as a flame failure.

What causes Lochinvar Flame Loss?

The most common causes are: Dirty flame rod; Unstable gas pressure; Wiring/grounding; Combustion fault. A licensed technician confirms which one applies before any part is replaced.

Can I fix Lochinvar Flame Loss myself?

No. Loss-of-flame and false-flame faults point to the flame-rectification circuit, a dirty flame sensor, a failing gas valve, or unstable combustion. Confirming the cause needs live flame-current (microamp) readings and combustion analysis — instrumented gas work reserved for licensed technicians. Repeatedly resetting the boiler without fixing the root cause can be unsafe and can cause further damage. Call GasBoilers.ca at 604-359-1081 for a licensed diagnosis.

Is the Lochinvar Flame Loss fault dangerous?

It can be. This fault involves combustion, gas or venting. If you ever smell gas, leave the building immediately and call 911 or FortisBC at 1-800-663-9911 from outside. Otherwise, switch the boiler off and book a licensed technician.

How much does it cost to fix Lochinvar Flame Loss in Greater Vancouver?

Cost depends on the root cause and any parts needed. We start with a flat-rate diagnostic, then quote the repair before any work begins — no surprises. Call 604-359-1081 for current pricing and same-day availability.

Lochinvar showing Flame Loss? We'll fix it right.

Licensed, Red Seal–certified gas technicians across Greater Vancouver. Upfront pricing, same-day service available.

Call NowFree Quote
After-Hours Emergency604-359-1081